Accessories

T

Flameproof Ex d • increased safety Ex e • for indoor & outdoor applications

1 HEXAGON HEAD PLUGS (code: T)

For cylindrical and tapered threads in Brass (code: OT), Nickel-pated brass (code: ON) and Aluminium (code: AL).
T1-foto-shape-e-r-enlarger-reducer-cylindrical-profile

2 RECESSED PLUGS (code: T)

For cylindrical threads in AISI316L Stainless steel (code: S6)
T2-foto-shape-e-r-enlarger-reducer-cylindrical-profile

3 RECESSED PLUGS (code: T)

For tapered threads in AISI316L Stainless steel (code: S6)
T3

Example Code

T-codice

Plugs (code: T)

Plugs are used to temporarily or permanently close 
unused cable entries.

Main regulatory requirements:

The user has to use only one adaptor for the assembly of a cable entry. The user mustn’t close an adaptor or a coupling with a plug. These accessories are intended for the assembly of a cable entry only. Accessories in aluminium are suitable only for Group II (Surface).

Application fields

Surface - Group II • Mines - Group I

Approvals / Certifications

ATEX certifi cate: INERIS 12 ATEX 0089X
IEC Ex certifi cate: IEC Ex INE 10.0014X
UKCA certifi cate: CML 21UKEX1589X,
EAC certifi cate: HACTXOЛ RU C-IT.AЯ45.B.00909
CCC Ex NEPSI certifi cate: Nr. 2021322313003705

Protection type

Ex db IIC • Ex eb II (gas) • Ex tb IIIC (dusts) • Ex db I • Ex eb I (mines)

EPL (Equipment protection level)

Zone 1-2: Mb mines • Gb, Gc gas
Zone 21-22: Db Dc combustible dusts

Execution

Ex db IIC • Ex eb II • Ex tb IIIC • Ex db I • Ex eb I Db according to
ATEX: EN IEC 60079-0:2018 • EN 60079-1:2014 •
EN IEC 60079-7:2015/A1:2018 • EN 60079-15:2010 •
EN 60079-31:2014 • EN 60529:1991
IEC Ex: IEC 60079-0:2017 • IEC 60079-1:2014 •
IEC 60079-7:2015/A1:2017 • IEC 60079-15:2017 •
IEC 60079-31:2013 • IEC 60529:1989+A1:1999+A2:2013

Ambient temperatures in services: sealing washers materials

Nylon sealing washer -40°C ÷ + 100°C
Silicone sealing washer -65°C ÷ + 220°C
PTFE sealing washer -65°C  ÷ + 220°C
Without sealing washer -70°C ÷ +400°C

Available materials

Brass (code: OT) • Nickel-plated brass (code: ON)
AISI316L Stainless steel (code: S6) • Aluminium (code: AL)

Available threads

ISO 262 Metrical • ISO 228 • DIN 40430 Pg
ANSI B1.20.1 NPT • EN 10226 Gk (only for ATEX)

Degree of protection

The cable glands degree of protection is IP66 or IP66/68, 30-meters depth for 7 days according to the IEC EN 60529 standard; the degree of protection IP 68 is obtained by using flat sealing rings on cable glands with cylindrical threads. Without gaskets, the degree of protection is IP 66. If the cable glands with cylindrical or tapered threads are screwed on the threaded hole of an apparatus, in order to guarantee an IP66 or IP66/68 degree of protection, threaded parts must be sealed with Loctite or similar. In order to maintain the IPX8 degree of protection,  the cable entry shall be fitted on enclosure witch satisfies an immersion test under 30 meters of water during 7 days. Metric cable glands are made in accordance to 
EN 62444 Standard.

T1-T2-tabella