Flameproof Ex d ˙ increased safety Ex e ˙ for indoor & outdoor applications

for armoured cables ˙ inner & outer sealing
foto-KTA-type-KT-series-rcn
KTA-esploso-21

Cable glands ktA type (code: KTA)

The sealing ring blocks the cable on the under armour diameter. The addition of the sealing ring on the outer sheath guarantees a complete protection of the cable armour. 
Cable glands EMC tested by triaxial method, according to 
IEC 62153-4-3, IEC 62153-4-4 standards. Metric cable glands are made according to EN 62444 standard. Maintenance and installation operations and product selection must be done in accordance with 
IEC EN 60079-14 and 17 standards.

Application fields

Surface - Group II

Approvals / Certifications

ATEX certifi cate: INERIS 16 ATEX 0045X
Type examination certifi cate: INERIS 17 ATEX 3004 (Ex nR IIC Gc)
IECEx certifi cate: IECEx INE 16.0054X
UKCA certifi cate: CML 21UKEX1592X
UKCA certifi cate (Cat 3): CML 21UKEX1593X
EAC certifi cate: HACTXOЛ RU C-IT.AЯ45.B.00909
CCC Ex NEPSI certifi cate: Nr. 2021322313003710

Protection type

Ex db IIC • Ex eb II (gas) • Ex tb IIIC (dusts)

EPL (Equipment protection level)

Zone 1-2: Gb, Gc gas
Zone 21-22: Db Dc combustible dusts

Execution

Ex db IIC • Ex eb II • Ex tb IIIC
according to
ATEX: EN IEC 60079-0:2018 • EN 60079-1:2014 •
EN IEC 60079-7:2015/A1:2018 • EN 60079-15:2010 •
EN 60079-31:2014 • EN 60529:1991
IEC Ex: IEC 60079-0:2017 • IEC 60079-1:2014 •
IEC 60079-7:2015/A1:2017 • IEC 60079-15:2017 •
IEC 60079-31:2013 • IEC 60529:1989+A1:1999+A2:2013

Ambient temperatures in services: sealing washers materials

Silicone seals -60°C ÷ + 80°C (code: SI)

Cable type

Armoured: Single armoured cable SWA, Alluminium wire armoured cable AWA,Alluminium strip armoured ASA. Single wire braided cable SWB, Steel tape armored cable STA, Pliable wire armoured cable PWA. Screened flexible wire braided cable CY-SY.

Available materials

Brass (code: OT) • Nickel-plated brass (code: ON)
AISI316L Stainless steel (code: S6) • Aluminium (code: AL)

Available threads

ISO 262 Metrical
ANSI B1.20.1 NPT
Upon request:
ISO 228
DIN 40430 Pg
EN 10226 Gk (only for ATEX)

Degree of protection

The degree of protection assured by the cable entries is IP66 according to IEC/EN 60529 standard. For cable entries with cylindrical thread the degree of protection IP66 is assured by using either a flat silicone MVQ gasket of a flat PTFE gasket or a SILICONE MVQ O-ring. For cable entries with conical thread the degree of protection IP66 is assured by applying to the threading of sealing LOCTITE 241.
Metric cable glands are made in accordance to EN 62444 Standard.

Example Code

example-code-kta-type-table-or
example-code-kta-type-table-ot-on-sa-al

Technical Drawing

technical-drawing-kta-type
KTA-type-table-details